Work Mode:
P1.1:Output keep ON for time OP after get trigger signal and then OFF;The input signal is invalid if get trigger signal again during delay time OP.
P1.2:Output keep ON for time OP after get trigger signal and then OFF;Output will restart delay if get trigger signal again during delay time OP.
P1.3:Output keep ON for time OP after get trigger signal and then OFF;Output will reset and stop timing if get trigger signal again during delay time OP.
P2:Output keep OFF for time CL after get trigger signal and then output keep ON for time OP and then output will OFF.
P3.1:Output keep ON for time OP after get trigger signal and then output keep OFF for time CL and then loops the above action.Output will reset and stop timing and output OFF if get trigger signal again during loops.The number of cycles (LOP) can be set.
P3.2:Output keep ON for time OP after power on without get trigger signal and then output keep OFF for time CL and then loops the above action.The number of cycles (LOP) can be set.Note:this mode no need input signal.
P4:Signal hold function.Reset delay time and relay keep ON if keep get trigger signal.Output OFF after delay time OP when the signal disappears.Reset delay time when get trigger signal again during timing.
Timing range:
1>.Continuously adjustable from 0.1 seconds to 999 minutes.
2>.Enter the settings interface when short press button ‘STOP’ in the OP / CL parameter modification interface(Flashing) to select timing range.
3>.Pay attention to the position where the decimal point moves when the button is pressed.
4>.Display ‘XXX’ No decimal point, the timing range is 1 second ~ 999 seconds.
5>.Display ‘XX.X’ The decimal point is the penultimate, timing range is 0.1 second to 99.9 seconds.
6>.Display ‘X.X.X’ The decimal point is fully lit, timing range is 1 minute to 999 minutes.
7>.For example, if you want to set the OP to 3.2 seconds, move the decimal point to the penultimate position, Screen will display ‘03.2’
8>.OP and CL parameters are the same in different work mode.
9>.It will display OP(CL,LOP) and corresponding delay time by short press button SET in main display interface(when display 000).
10>.It just display OP and corresponding delay time in P1 mode by short press button SET in main display interface.
Parameter Description:
OP: Delay time for turn On;
CL: Delay time Turn OFF;
LOP: Number of cycles.Range is 1-999tims.’----’ means unlimited loop.